WHICH LASER TYPE IS RIGHT
FOR YOU?
Nd:YAG lasers use a water cooling system to control temp. and have some consumable parts, such as a Yag lamp that has to be changed periodically depending on use.
Fiber lasers utilize semiconductor diodes as the pumping mechanism and a doped fiber optic cable as the gain medium. In a fiber laser, the doped fiber optic serves as the resonator. Fiber lasers are the most reliable laser technology available today for material processing applications, offering the best combination of reliability and marking capability.
The many pros of a fiber laser include:
- Highest beam quality
- Air cooled with high ambient air temperature operating capabilities
- Very efficient with low power consumption
- Longest diode life (Up to 100,000 hours)
- Less Optics Needed
- Easy to integrate and service
Technical Data | LWI V YAG 120 W |
---|---|
laser safety class | 4 |
beam source | Nd:YAG, flashlamp, pulsed |
wavelength | 1064 nm |
max. pulse energy | 70 joule |
max. peak power | 17 kW |
max. average power | 120 W |
energy adjustment mode | voltage or PWM mode |
voltage | 160-500V |
pulse width | 1-20 ms |
pulse frequency | 1-20 hz |
pulse fill | 10-100% |
PWM mode | 1 – 100 % |
focal length | 190 mm |
beam diameter | 200 µm – 2mm, motorized beam-expander |
microscope | Leica binocular, oculars magnification 20x |
illumination of workplace | dual LED cold-light, switchable |
parameter settings memory | 50 settings, individual named |
energy measurement system | integrated |
controller | multi-controller-system, self-diagnostic-system, plaintext for maintenance and status messages |
interface | RS232, CAN-Bus |
shielding gas supply | flexible nozzle, adjustable gas delay |
cooling system | integrated, closed, temperature controlled fan |
cooling option | – |
electrical supply | 3 phase, 400V, /50 hz |
power consumption | 4 kw |
dimensions | 1487mm x 995mm x 790mm |
Technical Data | LWI V YAG 150 W |
---|---|
laser safety class | 4 |
beam source | Nd:YAG, flashlamp, pulsed |
wavelength | 1064 nm |
max. pulse energy | 70 joule |
max. peak power | 17 kW |
max. average power | 150 W |
energy adjustment mode | voltage or PWM mode |
voltage | 160-500V |
pulse width | 1-20 ms |
pulse frequency | 1-20 hz |
pulse fill | 10-100% |
PWM mode | 1 – 100 % |
focal length | 190 mm |
beam diameter | 200 µm – 2mm, motorized beam-expander |
microscope | Leica binocular, oculars magnification 20x |
illumination of workplace | dual LED cold-light, switchable |
parameter settings memory | 50 settings, individual named |
energy measurement system | integrated |
controller | multi-controller-system, self-diagnostic-system, plaintext for maintenance and status messages |
interface | RS232, CAN-Bus |
shielding gas supply | flexible nozzle, adjustable gas delay |
cooling system | integrated, closed, temperature controlled fan |
cooling option | – |
electrical supply | 3 phase, 400V, /50 hz |
power consumption | 4 kw |
dimensions | 1487mm x 995mm x 790mm |
Technical Data | LWI V YAG 200 W |
---|---|
laser safety class | 4 |
beam source | Nd:YAG, flashlamp, pulsed |
wavelength | 1064 nm |
max. pulse energy | 70 joule |
max. peak power | 17 kW |
max. average power | 200 W |
energy adjustment mode | voltage or PWM mode |
voltage | 200-500V |
pulse width | 1-30 ms |
pulse frequency | 1-30 hz |
pulse fill | 10-100% |
PWM mode | 1 – 100 % |
focal length | 190 mm |
beam diameter | 200 µm – 2mm, motorized beam-expander |
microscope | Leica binocular, oculars magnification 20x |
illumination of workplace | dual LED cold-light, switchable |
parameter settings memory | 50 settings, individual named |
energy measurement system | integrated |
controller | multi-controller-system, self-diagnostic-system, plaintext for maintenance and status messages |
interface | RS232, CAN-Bus |
shielding gas supply | flexible nozzle, adjustable gas delay |
cooling system | integrated, closed, temperature controlled fan |
cooling option | – |
electrical supply | 3 phase, 400V, /50 hz |
power consumption | 4 kw |
dimensions | 1487mm x 995mm x 790mm |
Technical Data | LWI V YAG 300 W |
---|---|
laser safety class | 4 |
beam source | Nd:YAG, flashlamp, pulsed |
wavelength | 1064 nm |
max. pulse energy | 70 joule |
max. peak power | 17 kW |
max. average power | 300 W |
energy adjustment mode | voltage or PWM mode |
voltage | 200-500V |
pulse width | 1-30 ms |
pulse frequency | 1-30 hz |
pulse fill | 10-100% |
PWM mode | 1 – 100 % |
focal length | 190 mm |
beam diameter | 200 µm – 2mm, motorized beam-expander |
microscope | Leica binocular, oculars magnification 20x |
illumination of workplace | dual LED cold-light, switchable |
parameter settings memory | 50 settings, individual named |
energy measurement system | integrated |
controller | multi-controller-system, self-diagnostic-system, plaintext for maintenance and status messages |
interface | RS232, CAN-Bus |
shielding gas supply | flexible nozzle, adjustable gas delay |
cooling system | integrated, closed, temperature controlled fan |
cooling option | – |
electrical supply | 3 phase, 400V, /50 hz |
power consumption | 4 kw |
dimensions | 1487mm x 995mm x 790mm |
Intelligent Axis Control
Precisely controls axis movements. This extends manual welding by its sophisticated automatic and programable functions. Touchscreen and Joystick terminals directly in your workspace provide a unique, simple control concept. Thanks to the completely integrated hardware, a separate computer is not needed.
Pulse Distance Synchronization
Teach-In Programming
3PCD
Rotating Access Add-On
Pulse Width Modulation
Pulse Shaping
On Axis Light
On Axis Shielding Gas Supply
Laser Welding Quote Request
Alliance Specialties and Laser Sales
Alliance Laser Sales California
MACHINE SALES
LASER WELDING MACHINES
- VISION Unixx III
- VISION MobileFlexx
- VISION MobileFlexx ToolRoom
- VISION Ultra Flexx
- VISION Ergo
- VISION T-Base
- VISION Small Chamber
- ALLIANCE ID1-Fiber Laser
LASER ENGRAVING MACHINES
MOLD SERVICES
LASER WELDING MACHINES
STRATEGIC PARTNER